The Indian Railways has directed loco pilots to verify that brakes are working effectively before accelerating trains from originating stations, according to railway sources. Pilots taking charge of a train have been asked to carry out a "Brake Feel Test" after departure once the train reaches 15 kmph, feeling the brake application until the speed falls to 10 kmph, and then to proceed within prescribed speed limits. They have also been told to conduct a "Brake Power Test" after the train attains 60 to 70 kmph for passenger trains and 40 to 50 kmph for freight trains, observing brake application and brake power until speeds drop to 30 to 35 kmph and 20 to 25 kmph respectively. Assistant loco pilots have been instructed to monitor and ensure the tests are conducted without fail and to assess the braking system's effectiveness.
The directive follows two reported incidents of brake failure in the past month. Train 13125, the Kolkata-Sairang Express, derailed at Digaru railway station on the Northeast Frontier Railway on November 11, 2026; according to the loco pilot, the train, diverted to the loop line, could not be controlled despite the application of regular and emergency brakes and hit the dead end, derailing five coaches. In the second incident, on October 24, 2026, an empty rake of the Vande Bharat Express was allowed to run 463 km on the South Eastern Railway with poor braking power.
Railway sources said that on the South Eastern Railway, the loco pilot reported poor and ineffective brake power soon after the train departed Hatia and gave a written complaint at Ranchi, but officials allowed the train to proceed. A second crew that took over from Muri also reported poor brake performance, yet the train continued. A preliminary inquiry report sent by the South Eastern Railway headquarters to the Divisional Railway Manager, Ranchi, found failures on the part of various staff and said the train ran about 463 km without application of the train brakes, depending solely on locomotive and regenerative braking.
Safety experts have raised questions about the quality of inspection and operational alertness, saying such exercises should not be conducted merely as routine formalities.